Ultra - high temperature instantaneous sterilization machine UHT sterilizer beve
This equipment is suitable for instantaneous sterilization of liquid materials such as fresh milk, fruit juice, beverage, stick ice, ice cream paste, soy sauce, soy milk, condensed milk, alcohol and so on, and can also be used for sterilization of fluid material. The equipment of the feed and discharge are used three-way cock, the flow can be adjusted according to need to use reliable.
This equipment is suitable for instantaneous sterilization of liquid materials such as fresh milk, fruit juice, beverage, stick ice, ice cream paste, soy sauce, soy milk, condensed milk, alcohol and so on, and can also be used for sterilization of fluid material. The equipment of the feed and discharge are used three-way cock, the flow can be adjusted according to need to use reliable.
How the equipment works:
Features:
1, continuous production, sterilization time is very short.
2, due to short heating time to obtain quality products.
3, due to the use of ultra-high temperature sterilization, so sterilization effect is particularly good.
4, with the centrifugal pump or high pressure homogenizer in series, a wide range of applications, suitable for high viscosity material sterilization.
5, because the design of the use of hot and cold heat exchanger with waste heat utilization of economic effects, so the steam consumption is small.
Maintenance and troubleshooting:
1, regularly check the trap to prevent condensation of steam condensate blocked.
2, often check the safety valve, pressure gauge and thermometer is out of order.
3, if found to be a serious leak in the pump should be timely maintenance, if necessary, swap the end of the shaft seal.
4, such as the use of homogeneous machine at the same time, optional 3WR-1.5-type high-pressure pump, and according to the instructions required maintenance.
5. If the equipment is to be used in a frozen area during the winter deactivation, the water in the pipe should be drained or filled with 1% lye.
6, the pipe joints and cocks should always check whether the tight, not to leak or mixed into the air, because the material into the air will accelerate the formation of pipe wall fouling.
7, when the equipment is not used, the steam valve should be opened for future use.
8, the feed pump motor bearings should be cleaned each year, and the replacement of lubricants, the amount can not be too much, as long as half of the bearing shell filled on the line.
9, the feed pump is not allowed in the absence of liquid time and space.
10, the sudden elimination of power failure.